KROHNE IFC 100 MANUAL PDF

The IFC signal converter is designed to measure the flow velocity, IFC signal converter can be combined with any KROHNE flow. The Krohne IFC signal converter will need to be setup to output pulses from the flow meter. This guide will outline the procedure on the IFC signal. Ifc • Read online or download PDF • KROHNE IFC Converter Quickstart EN User Manual.

Author: Vumuro Gora
Country: Albania
Language: English (Spanish)
Genre: Health and Food
Published (Last): 23 June 2007
Pages: 58
PDF File Size: 19.39 Mb
ePub File Size: 19.9 Mb
ISBN: 976-8-40671-228-9
Downloads: 52151
Price: Free* [*Free Regsitration Required]
Uploader: Mautaur

Operation – KROHNE IFC 100 Converter EN User Manual

The pulse rate or the corresponding. For remote signal converters, check the connection of the signal cable.

F backup 2 settings F wiring A The current at the current input is less than 0. F field frequency too high.

For remote signal converters, check the. If “standard” is set, set field frequency in Fct. F active settings Error during the CRC check of the active settings. Application test or operator action necessary.

KROHNE IFC signal converter manual — Visaya eShop

Diagnostic function, conductivity measurement and simple navigation to name but a few. If this limit occurs sporadically in processes with air pockets, solid contents or low conductivity, then either the limit has to be increased or a pulse filter used so as to quell the error messages and also reduce the measurement errors.

  HABIB JALIB POETRY IN URDU PDF

F over range A The pulse rate or the corresponding measured value is limited by a filter setting. Open the catalog to page 8.

Hey guys, I bought a new IFC signal converter from Krohne and I am having trouble to find the technical manual on the website. Remote version in wall-mounted housing For temperature effects, vibration or in places that are difficult to access, remote installation is possible with the IFC W. Application fault, device OK, but measured values affected. Or the demanded pulse rate is too high. If you require data that is more relevant to your specific application, please contact us or your local sales office.

Group message, when errors as described below or other application errors occur. F backup 1 settings. Then when you switch to your desktop, you get deluged with too much information, taking way too long to find anything. But before I drop that link, let me introduce the class to your converter.

  HIDROCOLOIDES REVERSIBLES E IRREVERSIBLES PDF

You have one of those, right? Sie finden sie in unserem Multimarken- eShop. Diese Information hilft uns um eine professionelle Community bei Visaya aufzubauen. Open the catalog to page 1. Measured values are still supplied, but they are always too low.

F flow exceeding limit. The sensor electronics will use one or the other function setting to zero or kkrohne measurement depending on a selection made by the user. The Online Industrial Exhibition. Ambient temperature Depending on the version and combination of outputs. No message if coil broken or bridged. F flow exceeding limit Measuring range exceeded, filter setting limits measured values. The current or the corresponding measured. Current not correct, mA output cable has. As with any electromagnetic flow meteryou need to install it carefully.

The website lists many possible applications, industry focuses, and application cases. No message if empty pipe.